RoHS Screening Report |
Purpose of this report is to determine the restricted elements in accordance with Directive 2011/65/EU of the European Parliament and of the Council of, 8 June 2011 and its amendments. |
 |
Pass |
The results comply with the Directive 2011/65/EU of the European Parliament and of the Council of, 8 June 2011 and its amendments. |
 |
Failed |
Samples are higher than the limited values. |
|
Part Number: 83110141 |
Description: Two Function Power Entry Module |
Date: 11/09/09 |
Method of Screening: Thermo Scientific Niton Analyzer XL3t 700 Serial no. 30495 |
Component
Description |
Cadmium (Cd)
<100 PPM
<0.01% |
Lead
(pb)
<1000 PPM <0.10%
|
Mercury (Hg)
<1000 PPM <0.10%
|
Chromium (Cr)
<1000 PPM <0.10%
|
PBB
/PBDE
Br (Brominates)
<1000 PPM
<0.10%
|
BBP
<0.10%
|
DBP
<0.10%
|
DIBP
<0.10%
|
DEHP
<0.10%
|
Compliant |
Remarks |
Body Plastic |
N/D |
N/D |
N/D |
N/D |
N/D |
N/D |
N/D |
N/D |
N/D |
yes |
|
Contacts |
N/D |
N/D |
N/D |
0.080 % |
N/D |
N/D |
N/D |
N/D |
N/D |
yes |
Does not contain Hexavalent Chromium. |
ND = Not Detected |
N/A = Not Applicable |
PPM = Parts Per Million |
"K" = Kilo means thousands (1000) |
Comments: |
Contacts: Brass:Pins, Nickel Plated. Tabs, Tin Plated. |

Joe Caligiuri
Product Compliance Specialist
Interpower Corporation
This screening report cannot be reproduced without prior written permission from Interpower Corporation. Unless otherwise stated: (a) the results shown in this document refer only to the sample(s) analyzed and (b) such sample(s) are retained for 30 days.
|
Form: XLT screening report
3-2008 |
Page 1 of 1 |
|