Purpose of this report is to determine the restricted elements in accordance with Directive 2011/65/EU of the European Parliament and of the Council of, 8 June 2011 and its amendments.
Pass
The results comply with the Directive 2011/65/EU of the European Parliament and of the Council of, 8 June 2011 and its amendments.
Failed
Samples are higher than the limited values.
Part Number: 88052030
Description: Danish Black 13A/250VAC Socket
Date: 07/12/11
Method of Screening: Thermo Scientific Niton Analyzer XL3t 700 Serial no. 30495
Component
Description
Cadmium (Cd)
<100 PPM
<0.01%
Lead
(pb)
<1000 PPM <0.10%
Mercury (Hg)
<1000 PPM <0.10%
Chromium (Cr)
<1000 PPM <0.10%
PBB
/PBDE
Br (Brominates)
<1000 PPM
<0.10%
BBP
<0.10%
DBP
<0.10%
DIBP
<0.10%
DEHP
<0.10%
Compliant
Remarks
Brass
N/D
N/D
N/D
0.532%
N/D
N/D
N/D
N/D
N/D
yes
Plastic Black
N/D
N/D
N/D
N/D
123Kppm
N/D
N/D
N/D
N/D
yes
Does not contain restricted Brominates.
Plastic Blue
N/D
N/D
N/D
N/D
9.30ppm
N/D
N/D
N/D
N/D
yes
Plastic White
N/D
N/D
N/D
N/D
14K ppm
N/D
N/D
N/D
N/D
yes
Does not contain restricted Brominates.
Screws Silver
N/D
N/D
N/D
0.086%
N/D
N/D
N/D
N/D
N/D
yes
ND =Not Detected
N/A = Not Applicable
PPM = Parts Per Million
"K"= Kilo means thousands (1000)
Comments:
Joe Caligiuri
Product Compliance Specialist
Interpower Corporation