UL / CSA Classification of cords

S = Service Grade (also means extra hard service when not followed by J, V, or P)
J = Hard Service
V = Vacuum cleaner cord (also light duty cable)
P = Parallel cord (also known as zip cord) – Always light duty
E = Thermoplastic Elastomer (UL/NEC designation ONLY)
O = Oil Resistant*
T = Thermoplastic
W = Outdoor-includes sunlight resistant jacket and wet location rated conductors
(formerly “W-A”)

H
= Heater cable
VW-1 = Flame retardant
FT2 = Flame retardant
* When only one “O” appears in a classification (i.e. SJEOW), only the outer jacket material is oil resistant. If two “O’s” are in the classification (i.e. SEOOW), the insulation covering the conductors and the outer jacket insulation are all oil resistant 

 

 
UL/CSA Classification of cords
 
  PVC     TPE  
                     
 

 

UL Types CSA Types
SVT SVT
SJT SJT
SJTW SJTW
SJTO SJTO
SJTOW SJTOW
ST ST
STW STW
STO STO
STOW STOW
SPT-1 SPT-1
SPT-2 SPT-2
SPT-3 SPT-3
           
       

UL Types CSA Types
SJT SJT-TPE
SJEW SJTW-TPE
SJEO SJTO-TPE
SJEOW SJTOW-TPE
SJEOO SJTOO-TPE
SE ST-TPE
SEW ST-TPE
SEO STO-TPE
SEOW STOW-TPE
SEOW STOW-TPE
SEOO STOO-TPE
SEOOW STOOW-TPE
   
                 
  Thermoset          
                     
 
UL Types CSA Types
S S
SO SOW
SOW SOW
SOO SOO
SOOW SOOW
SJ SJ
SJO SJO
SJOW SJOW
SJOO SJOO
SJOOW SJOOW